RTU5024 SMS-kommandon
22 kommandon. Tryck på kopieringsknappen för att kopiera exempelkommandot och klistra in det i din SMS-app.
Standardlösenord: 1234
Initialize (REQUIRED first step)
adminRegister the module's SIM card number. This is the FIRST command you must send. Use 00 prefix instead of +.
Syntax
{pwd}TEL{moduleSIM}# Exempel
1234TEL00861351015# Svar
Set Success! Syntax
{pwd}TEL{moduleSIM}# Exempel
1234TEL00861351015# Svar
Set Success! Sync clock
adminSet the module's internal clock. Required for time-limited users to work correctly.
Syntax
{pwd}T{YYMMDDHHmm}# Exempel
1234T2603291530# Svar
Set Time OK! Syntax
{pwd}T{YYMMDDHHmm}# Exempel
1234T2603291530# Svar
Set Time OK! Change password
adminChange device password to new 4-digit password.
Syntax
{pwd}P{newpwd} Exempel
1234P6666 Svar
Password changed to {newpwd}, please remember it carefully. Syntax
{pwd}P{newpwd} Exempel
1234P6666 Svar
Password changed to {newpwd}, please remember it carefully. Add permanent user
adminAdd authorized user to slot (001-200). Always allowed to call and control.
Syntax
{pwd}A{slot}#{phone}# Exempel
1234A003#123456# Svar
User added confirmation Syntax
{pwd}A{slot}#{phone}# Exempel
1234A003#123456# Svar
User added confirmation Add time-limited user
adminAdd user with access limited to a date/time range. Clock must be synced first.
Syntax
{pwd}A{slot}#{phone}#{startYYMMDDHHmm}#{endYYMMDDHHmm}# Exempel
1234A016#123456#1502050800#1502051000# Svar
User added confirmation Syntax
{pwd}A{slot}#{phone}#{startYYMMDDHHmm}#{endYYMMDDHHmm}# Exempel
1234A016#123456#1502050800#1502051000# Svar
User added confirmation Query user by slot
adminCheck which phone number is stored at a position.
Syntax
{pwd}A{slot}# Exempel
1234A002# Svar
Phone number at slot or Empty Syntax
{pwd}A{slot}# Exempel
1234A002# Svar
Phone number at slot or Empty Batch query users
adminQuery authorized numbers from slot range. Returns multiple SMS (10 numbers per SMS).
Syntax
{pwd}AL{slotStart}#{slotEnd}# Exempel
1234AL002#050# Svar
List of users across multiple SMS Syntax
{pwd}AL{slotStart}#{slotEnd}# Exempel
1234AL002#050# Svar
List of users across multiple SMS Delete user
adminRemove authorized number at position (or overwrite with new number).
Syntax
{pwd}A{slot}## Exempel
1234A002## Svar
User deleted Syntax
{pwd}A{slot}## Exempel
1234A002## Svar
User deleted Allow all callers
adminAllow any phone number to trigger the relay. WARNING: free access for anyone.
Syntax
{pwd}ALL# Exempel
1234ALL# Svar
Allow all mode set Syntax
{pwd}ALL# Exempel
1234ALL# Svar
Allow all mode set Authorized users only (default)
adminOnly authorized numbers can trigger the relay. Recommended setting.
Syntax
{pwd}AUT# Exempel
1234AUT# Svar
Authorized only mode set Syntax
{pwd}AUT# Exempel
1234AUT# Svar
Authorized only mode set Set relay close time
adminHow long relay stays closed (ON) after call. 000=0.5s latch, 001-998=seconds, 999=stays on until next call.
Syntax
{pwd}GOT{seconds}# Exempel
1234GOT030# Svar
Relay time set Syntax
{pwd}GOT{seconds}# Exempel
1234GOT030# Svar
Relay time set Configure relay ON SMS
adminSet who receives SMS when relay turns ON and what it says. a=first user (0/1), b=caller (0/1).
Syntax
{pwd}GON{ab}#{content}# Exempel
1234GON11#DoorOpen# Svar
Confirmation set Syntax
{pwd}GON{ab}#{content}# Exempel
1234GON11#DoorOpen# Svar
Confirmation set Configure relay OFF SMS
adminSet who receives SMS when relay turns OFF and what it says.
Syntax
{pwd}GOFF{ab}#{content}# Exempel
1234GOFF00#DoorClose# Svar
Confirmation set Syntax
{pwd}GOFF{ab}#{content}# Exempel
1234GOFF00#DoorClose# Svar
Confirmation set Disable relay ON SMS
adminNo SMS notification when relay turns ON.
Syntax
{pwd}GON## Exempel
1234GON## Svar
ON notification disabled Syntax
{pwd}GON## Exempel
1234GON## Svar
ON notification disabled Disable relay OFF SMS
adminNo SMS notification when relay turns OFF.
Syntax
{pwd}GOFF## Exempel
1234GOFF## Svar
OFF notification disabled Syntax
{pwd}GOFF## Exempel
1234GOFF## Svar
OFF notification disabled Relay ON (by SMS)
all authorizedTurn relay on via SMS command. Close time follows GOT setting.
Syntax
{pwd}CC Exempel
1234CC Svar
Relay ON (or custom GON content) Syntax
{pwd}CC Exempel
1234CC Svar
Relay ON (or custom GON content) Relay OFF (by SMS)
all authorizedTurn relay off via SMS command.
Syntax
{pwd}DD Exempel
1234DD Svar
Relay OFF (or custom GOFF content) Syntax
{pwd}DD Exempel
1234DD Svar
Relay OFF (or custom GOFF content) Check status
all authorizedQuery relay state, signal strength, and device info.
Syntax
{pwd}EE Exempel
1234EE Svar
Relay status, GSM signal value, firmware info Syntax
{pwd}EE Exempel
1234EE Svar
Relay status, GSM signal value, firmware info Set auto-report interval
adminAuto-send status report to first user every X hours. 000=disabled (default).
Syntax
{pwd}T#{hours}# Exempel
1234T#024# Svar
Auto-report set Syntax
{pwd}T#{hours}# Exempel
1234T#024# Svar
Auto-report set Query auto-report interval
adminCheck current auto-report interval.
Syntax
{pwd}T# Exempel
1234T# Svar
Current interval in hours Syntax
{pwd}T# Exempel
1234T# Svar
Current interval in hours Query IMEI and firmware
adminGet the module's IMEI code and firmware version.
Syntax
{pwd}IMEI# Exempel
1234IMEI# Svar
IMEI and firmware info Syntax
{pwd}IMEI# Exempel
1234IMEI# Svar
IMEI and firmware info Factory reset
physical button or SMSReset to factory settings. Authorized users are preserved. Can also hold reset button on device.
Syntax
RESET Exempel
RESET Svar
Device restarts Syntax
RESET Exempel
RESET Svar
Device restarts