GSM-KEY-DC200 Comandi SMS
25 comandi. Tocca il pulsante copia per copiare il comando di esempio, poi incollalo nella tua app SMS.
Password predefinita: 123456
Change password
adminChange device password. Must enter new password twice.
Sintassi
#PWD{pwd}#CAP{newpwd}#CAP{newpwd} Esempio
#PWD123456#CAP333444#CAP333444 Risposta
PWD SETUP OK Sintassi
#PWD{pwd}#CAP{newpwd}#CAP{newpwd} Esempio
#PWD123456#CAP333444#CAP333444 Risposta
PWD SETUP OK Add permanent user (WHL)
adminAdd permanent user to whitelist slot (1-200). Max 10 digit phone number, strip country code.
Sintassi
#PWD{pwd}#WHL{slot}={phone} Esempio
#PWD123456#WHL001=61143815 Risposta
WHL01 SET TO 61143815 OK Sintassi
#PWD{pwd}#WHL{slot}={phone} Esempio
#PWD123456#WHL001=61143815 Risposta
WHL01 SET TO 61143815 OK Query permanent user slot
adminCheck which phone is in a permanent slot
Sintassi
#PWD{pwd}#WHL{slot}? Esempio
#PWD123456#WHL001? Risposta
WHL001 IS 61143815 OK Sintassi
#PWD{pwd}#WHL{slot}? Esempio
#PWD123456#WHL001? Risposta
WHL001 IS 61143815 OK Delete permanent user
adminRemove user from permanent whitelist (or overwrite with new number)
Sintassi
#PWD{pwd}#WHL{slot}=0000000 Esempio
#PWD123456#WHL001=0000000 Risposta
WHL001 SET TO 00000000 Sintassi
#PWD{pwd}#WHL{slot}=0000000 Esempio
#PWD123456#WHL001=0000000 Risposta
WHL001 SET TO 00000000 List all permanent users (PC only)
adminList all numbers in the whitelist. Only works via PC software, not SMS.
Sintassi
#PWD{pwd}#WHL=ALL? Esempio
#PWD123456#WHL=ALL? Risposta
WHL001 IS XXX
WHL003 IS XXX
... Sintassi
#PWD{pwd}#WHL=ALL? Esempio
#PWD123456#WHL=ALL? Risposta
WHL001 IS XXX
WHL003 IS XXX
... Add weekly schedule user (SHL)
adminAdd user with weekly day+time schedule. Days: 1=Mon..7=Sun. 50 slots.
Sintassi
#PWD{pwd}#SHL{slot}={phone}:{days}({startTime}-{endTime}) Esempio
#PWD123456#SHL001=13564121668:1357(8:32-23:59) Risposta
SHL001 SETUP TO 61143815 :1357(8:32-23:59) Sintassi
#PWD{pwd}#SHL{slot}={phone}:{days}({startTime}-{endTime}) Esempio
#PWD123456#SHL001=13564121668:1357(8:32-23:59) Risposta
SHL001 SETUP TO 61143815 :1357(8:32-23:59) Add date-range user (PHL)
adminAdd user with access limited to a date range and daily time window. 50 slots. Date format: YYMMDD.
Sintassi
#PWD{pwd}#PHL{slot}={phone}:{startDate}-{endDate}({startTime}-{endTime}) Esempio
#PWD123456#PHL001=13564121668:100324-101012(8:32-18:26) Risposta
PHL001 SETUP TO 61143815 : 100324-100812(8:32-18:26) Sintassi
#PWD{pwd}#PHL{slot}={phone}:{startDate}-{endDate}({startTime}-{endTime}) Esempio
#PWD123456#PHL001=13564121668:100324-101012(8:32-18:26) Risposta
PHL001 SETUP TO 61143815 : 100324-100812(8:32-18:26) Add count-limited user (QHL)
adminAdd user with limited number of uses. Expires after {count} activations. 550 slots.
Sintassi
#PWD{pwd}#QHL{slot}={phone}:{count} Esempio
#PWD123456#QHL001=13564121668:12 Risposta
QHL001 SETUP TO 61143815 :12 Sintassi
#PWD{pwd}#QHL{slot}={phone}:{count} Esempio
#PWD123456#QHL001=13564121668:12 Risposta
QHL001 SETUP TO 61143815 :12 Query special list user (SHL/PHL/QHL)
adminCheck which phone is in a special list slot. Replace {type} with SHL, PHL, or QHL.
Sintassi
#PWD{pwd}#{type}{slot}? Esempio
#PWD123456#SHL001? Risposta
SHL01 IS 61143815 OK Sintassi
#PWD{pwd}#{type}{slot}? Esempio
#PWD123456#SHL001? Risposta
SHL01 IS 61143815 OK Delete special list user (SHL/PHL/QHL)
adminRemove user from a special list slot. Replace {type} with SHL, PHL, or QHL.
Sintassi
#PWD{pwd}#{type}{slot}=0000 Esempio
#PWD123456#PHL01=0000 Risposta
{type}{slot} SET TO 0000 Sintassi
#PWD{pwd}#{type}{slot}=0000 Esempio
#PWD123456#PHL01=0000 Risposta
{type}{slot} SET TO 0000 List all special users (PC only)
adminList all numbers in special lists. Only works via PC software.
Sintassi
#PWD{pwd}#SHL=ALL? Esempio
#PWD123456#SHL=ALL? Risposta
SHL01 IS XXX
QHL08 IS XXX
... Sintassi
#PWD{pwd}#SHL=ALL? Esempio
#PWD123456#SHL=ALL? Risposta
SHL01 IS XXX
QHL08 IS XXX
... Set relay delay (gate pulse time)
adminSet relay pulse duration in MILLISECONDS. Default is 300ms.
Sintassi
#PWD{pwd}#GOT{milliseconds} Esempio
#PWD123456#GOT500 Risposta
DELAY TIME SET TO 0500MS Sintassi
#PWD{pwd}#GOT{milliseconds} Esempio
#PWD123456#GOT500 Risposta
DELAY TIME SET TO 0500MS Query relay delay
adminCheck current relay delay setting
Sintassi
#PWD{pwd}#GOT? Esempio
#PWD123456#GOT? Risposta
DELAY TIME IS 0500 MS Sintassi
#PWD{pwd}#GOT? Esempio
#PWD123456#GOT? Risposta
DELAY TIME IS 0500 MS Set relay mode - Momentary pulse
adminSet relay to momentary pulse mode (click and release). Default mode.
Sintassi
#PWD{pwd}#MODE0 Esempio
#PWD123456#MODE0 Risposta
RELAY SET TO MODE0 Sintassi
#PWD{pwd}#MODE0 Esempio
#PWD123456#MODE0 Risposta
RELAY SET TO MODE0 Set relay mode - Ratchet/toggle
adminSet relay to ratchet/toggle mode (stays on until next call toggles it off)
Sintassi
#PWD{pwd}#MODE1 Esempio
#PWD123456#MODE1 Risposta
RELAY SET TO MODE1 Sintassi
#PWD{pwd}#MODE1 Esempio
#PWD123456#MODE1 Risposta
RELAY SET TO MODE1 Check signal strength
adminQuery GSM signal quality (0-32). Above 12 is usable, above 16 is good.
Sintassi
#PWD{pwd}#CSQ? Esempio
#PWD123456#CSQ? Risposta
CSQ IS 26 Sintassi
#PWD{pwd}#CSQ? Esempio
#PWD123456#CSQ? Risposta
CSQ IS 26 Check status
adminFull device status including alarm config, relay delay, user count, signal, relay state.
Sintassi
#PWD{pwd}#STATUS? Esempio
#PWD123456#STATUS? Risposta
ALARM1=ON:SMS:10,ALARM2=ON:SMS:20,GOT=1000,WHL=85,ALARM1=H,ALARM2=H,BCPW=34,CSQ=20,RELAY=ON Sintassi
#PWD{pwd}#STATUS? Esempio
#PWD123456#STATUS? Risposta
ALARM1=ON:SMS:10,ALARM2=ON:SMS:20,GOT=1000,WHL=85,ALARM1=H,ALARM2=H,BCPW=34,CSQ=20,RELAY=ON Add alarm phone number
adminAdd phone number to receive alarm notifications (max 5 numbers)
Sintassi
#PWD{pwd}#ALARM{slot}={phone} Esempio
#PWD123456#ALARM01=13818120592 Risposta
ALARM01 SET TO 61143815 OK Sintassi
#PWD{pwd}#ALARM{slot}={phone} Esempio
#PWD123456#ALARM01=13818120592 Risposta
ALARM01 SET TO 61143815 OK Query alarm phone number
adminCheck which phone is in an alarm slot
Sintassi
#PWD{pwd}#ALARM{slot}? Esempio
#PWD123456#ALARM01? Risposta
ALARM01 IS 61143815 OK Sintassi
#PWD{pwd}#ALARM{slot}? Esempio
#PWD123456#ALARM01? Risposta
ALARM01 IS 61143815 OK List all alarm numbers
adminList all alarm notification numbers
Sintassi
#PWD{pwd}#ALARM=ALL? Esempio
#PWD123456#ALARM=ALL? Risposta
ALARM IS XXXXX:XXXX:XXXXXXX:0000:0000 Sintassi
#PWD{pwd}#ALARM=ALL? Esempio
#PWD123456#ALARM=ALL? Risposta
ALARM IS XXXXX:XXXX:XXXXXXX:0000:0000 Configure alarm inputs
adminConfigure alarm input behavior. State: ON/OFF. Mode: SMS or PHONE. Duration: seconds the input must be held to trigger.
Sintassi
#PWD{pwd}#ALARM-IN1={state}:{mode}:{duration},ALARM-IN2={state}:{mode}:{duration} Esempio
#PWD123456#ALARM-IN1=ON:SMS:2,ALARM-IN2=ON:PHONE:3 Risposta
ALARM_IN1=ON:SMS:2, ALARM_IN2=ON:PHONE:3 Sintassi
#PWD{pwd}#ALARM-IN1={state}:{mode}:{duration},ALARM-IN2={state}:{mode}:{duration} Esempio
#PWD123456#ALARM-IN1=ON:SMS:2,ALARM-IN2=ON:PHONE:3 Risposta
ALARM_IN1=ON:SMS:2, ALARM_IN2=ON:PHONE:3 Set alarm SMS text
adminConfigure custom SMS text sent when alarm inputs are triggered
Sintassi
#PWD{pwd}#UDI1:{text1},UDI2:{text2} Esempio
#PWD123456#UDI1:INTRUDER ALERT,UDI2:GATE PROBLEM Risposta
UDI1:INTRUDER ALERT, UDI2:GATE PROBLEM OKAY Sintassi
#PWD{pwd}#UDI1:{text1},UDI2:{text2} Esempio
#PWD123456#UDI1:INTRUDER ALERT,UDI2:GATE PROBLEM Risposta
UDI1:INTRUDER ALERT, UDI2:GATE PROBLEM OKAY Set timer-update phone number
adminDesignate which phone number can update the device clock (required for SHL/PHL time features)
Sintassi
#PWD{pwd}#TIMER-UPDATE:{phone} Esempio
#PWD123456#TIMER-UPDATE:96754667 Risposta
#PWD123456#TIMER-UPDATE: 96754667 OK Sintassi
#PWD{pwd}#TIMER-UPDATE:{phone} Esempio
#PWD123456#TIMER-UPDATE:96754667 Risposta
#PWD123456#TIMER-UPDATE: 96754667 OK Sync device clock
designated timer phone onlyUpdate the device's internal clock. Must be sent from the designated timer-update phone number.
Sintassi
#CLOCK Esempio
#CLOCK Risposta
CLOCK UPDATE TO 2010-10-18,16:58:10 Sintassi
#CLOCK Esempio
#CLOCK Risposta
CLOCK UPDATE TO 2010-10-18,16:58:10 Set service center address
adminSet the SMS service center address (usually not needed, auto-configured by SIM)
Sintassi
#PWD{pwd}#SCA{number} Esempio
#PWD123456#SCA+31612345678 Risposta
SCA SET OK Sintassi
#PWD{pwd}#SCA{number} Esempio
#PWD123456#SCA+31612345678 Risposta
SCA SET OK