RTU5024 Comandi SMS
22 comandi. Tocca il pulsante copia per copiare il comando di esempio, poi incollalo nella tua app SMS.
Password predefinita: 1234
Initialize (REQUIRED first step)
adminRegister the module's SIM card number. This is the FIRST command you must send. Use 00 prefix instead of +.
Sintassi
{pwd}TEL{moduleSIM}# Esempio
1234TEL00861351015# Risposta
Set Success! Sintassi
{pwd}TEL{moduleSIM}# Esempio
1234TEL00861351015# Risposta
Set Success! Sync clock
adminSet the module's internal clock. Required for time-limited users to work correctly.
Sintassi
{pwd}T{YYMMDDHHmm}# Esempio
1234T2603291530# Risposta
Set Time OK! Sintassi
{pwd}T{YYMMDDHHmm}# Esempio
1234T2603291530# Risposta
Set Time OK! Change password
adminChange device password to new 4-digit password.
Sintassi
{pwd}P{newpwd} Esempio
1234P6666 Risposta
Password changed to {newpwd}, please remember it carefully. Sintassi
{pwd}P{newpwd} Esempio
1234P6666 Risposta
Password changed to {newpwd}, please remember it carefully. Add permanent user
adminAdd authorized user to slot (001-200). Always allowed to call and control.
Sintassi
{pwd}A{slot}#{phone}# Esempio
1234A003#123456# Risposta
User added confirmation Sintassi
{pwd}A{slot}#{phone}# Esempio
1234A003#123456# Risposta
User added confirmation Add time-limited user
adminAdd user with access limited to a date/time range. Clock must be synced first.
Sintassi
{pwd}A{slot}#{phone}#{startYYMMDDHHmm}#{endYYMMDDHHmm}# Esempio
1234A016#123456#1502050800#1502051000# Risposta
User added confirmation Sintassi
{pwd}A{slot}#{phone}#{startYYMMDDHHmm}#{endYYMMDDHHmm}# Esempio
1234A016#123456#1502050800#1502051000# Risposta
User added confirmation Query user by slot
adminCheck which phone number is stored at a position.
Sintassi
{pwd}A{slot}# Esempio
1234A002# Risposta
Phone number at slot or Empty Sintassi
{pwd}A{slot}# Esempio
1234A002# Risposta
Phone number at slot or Empty Batch query users
adminQuery authorized numbers from slot range. Returns multiple SMS (10 numbers per SMS).
Sintassi
{pwd}AL{slotStart}#{slotEnd}# Esempio
1234AL002#050# Risposta
List of users across multiple SMS Sintassi
{pwd}AL{slotStart}#{slotEnd}# Esempio
1234AL002#050# Risposta
List of users across multiple SMS Delete user
adminRemove authorized number at position (or overwrite with new number).
Sintassi
{pwd}A{slot}## Esempio
1234A002## Risposta
User deleted Sintassi
{pwd}A{slot}## Esempio
1234A002## Risposta
User deleted Allow all callers
adminAllow any phone number to trigger the relay. WARNING: free access for anyone.
Sintassi
{pwd}ALL# Esempio
1234ALL# Risposta
Allow all mode set Sintassi
{pwd}ALL# Esempio
1234ALL# Risposta
Allow all mode set Authorized users only (default)
adminOnly authorized numbers can trigger the relay. Recommended setting.
Sintassi
{pwd}AUT# Esempio
1234AUT# Risposta
Authorized only mode set Sintassi
{pwd}AUT# Esempio
1234AUT# Risposta
Authorized only mode set Set relay close time
adminHow long relay stays closed (ON) after call. 000=0.5s latch, 001-998=seconds, 999=stays on until next call.
Sintassi
{pwd}GOT{seconds}# Esempio
1234GOT030# Risposta
Relay time set Sintassi
{pwd}GOT{seconds}# Esempio
1234GOT030# Risposta
Relay time set Configure relay ON SMS
adminSet who receives SMS when relay turns ON and what it says. a=first user (0/1), b=caller (0/1).
Sintassi
{pwd}GON{ab}#{content}# Esempio
1234GON11#DoorOpen# Risposta
Confirmation set Sintassi
{pwd}GON{ab}#{content}# Esempio
1234GON11#DoorOpen# Risposta
Confirmation set Configure relay OFF SMS
adminSet who receives SMS when relay turns OFF and what it says.
Sintassi
{pwd}GOFF{ab}#{content}# Esempio
1234GOFF00#DoorClose# Risposta
Confirmation set Sintassi
{pwd}GOFF{ab}#{content}# Esempio
1234GOFF00#DoorClose# Risposta
Confirmation set Disable relay ON SMS
adminNo SMS notification when relay turns ON.
Sintassi
{pwd}GON## Esempio
1234GON## Risposta
ON notification disabled Sintassi
{pwd}GON## Esempio
1234GON## Risposta
ON notification disabled Disable relay OFF SMS
adminNo SMS notification when relay turns OFF.
Sintassi
{pwd}GOFF## Esempio
1234GOFF## Risposta
OFF notification disabled Sintassi
{pwd}GOFF## Esempio
1234GOFF## Risposta
OFF notification disabled Relay ON (by SMS)
all authorizedTurn relay on via SMS command. Close time follows GOT setting.
Sintassi
{pwd}CC Esempio
1234CC Risposta
Relay ON (or custom GON content) Sintassi
{pwd}CC Esempio
1234CC Risposta
Relay ON (or custom GON content) Relay OFF (by SMS)
all authorizedTurn relay off via SMS command.
Sintassi
{pwd}DD Esempio
1234DD Risposta
Relay OFF (or custom GOFF content) Sintassi
{pwd}DD Esempio
1234DD Risposta
Relay OFF (or custom GOFF content) Check status
all authorizedQuery relay state, signal strength, and device info.
Sintassi
{pwd}EE Esempio
1234EE Risposta
Relay status, GSM signal value, firmware info Sintassi
{pwd}EE Esempio
1234EE Risposta
Relay status, GSM signal value, firmware info Set auto-report interval
adminAuto-send status report to first user every X hours. 000=disabled (default).
Sintassi
{pwd}T#{hours}# Esempio
1234T#024# Risposta
Auto-report set Sintassi
{pwd}T#{hours}# Esempio
1234T#024# Risposta
Auto-report set Query auto-report interval
adminCheck current auto-report interval.
Sintassi
{pwd}T# Esempio
1234T# Risposta
Current interval in hours Sintassi
{pwd}T# Esempio
1234T# Risposta
Current interval in hours Query IMEI and firmware
adminGet the module's IMEI code and firmware version.
Sintassi
{pwd}IMEI# Esempio
1234IMEI# Risposta
IMEI and firmware info Sintassi
{pwd}IMEI# Esempio
1234IMEI# Risposta
IMEI and firmware info Factory reset
physical button or SMSReset to factory settings. Authorized users are preserved. Can also hold reset button on device.
Sintassi
RESET Esempio
RESET Risposta
Device restarts Sintassi
RESET Esempio
RESET Risposta
Device restarts